<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22284</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: System pressure out of tollerance. Please run cal pressure
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
This may be reported as a warning or an error. If either main or
picker pressure is read more than 1.7 psi above or below the design
pressure, this will suspend with an error.
</text></DescriptionText>
<DescriptionText><text>
When it detects the pressure too high, then it attempts to lower the
pressure by bleeding some air out of the table cups. If this fixes the
problem then only a warning is displayed, but it should be a heads up
to visit the site and run cal pressure before it goes hard down.
</text></DescriptionText>
<DescriptionText><text>
If only one sensor is reading wrong, it may be caused by the sensor.
</text></DescriptionText>
<DescriptionText><text>
Check cal pressure flow.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Resume if possible, otherwise call Creo Response Center.
Check that inlet pressure is above 90 psi
</text></DescriptionText>
</OperatorAction>
<Cause>
Either main or picker pressure is more than 1.7 psi above or below the design
pressure.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/cal_pressure.xml</LinkAddress><LinkTitle>Command: cal pressure</LinkTitle></Link>
<Link><LinkAddress>../commands/ale.xml</LinkAddress><LinkTitle>Command: ale</LinkTitle></Link>
<Link><LinkAddress>../commands/picker.xml</LinkAddress><LinkTitle>Command: picker</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_cfg_ppsc.xml</LinkAddress><LinkTitle>NVS: al ppsc</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_cfg_mpsc.xml</LinkAddress><LinkTitle>NVS: al mpsc</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:03 2008 PST
</Updated>
<Links>
</Links>
</Error>